TT101R Smart Temperature Transmitter

TT101R Smart Temperature Transmitter ■Application ● Universal thermal resistance type intelli
  • tel:0086 550 7623999、0086 550 7623888
  • fax:0550-7623199 ext 0
  • email:xinguo@xinguo.net
Description

 

TT101R Smart Temperature Transmitter


■Application


● Universal thermal resistance type intelligent temperature transmitter, used to convert various thermal resistance input signals


It is a 4~20mA signal.


● Accept thermal resistance (RTD) signal input.


● Compact structure, can be directly installed in the junction box (Form B) of thermal resistance and thermocouple,


Optional special card can realize DIN35 rail installation.


■Features


● Compact structure.


● Easy to install, the central opening allows you to choose any installation method you want.


● Sensors monitor open and short circuits.


● Self-monitoring.


● It can be configured through a special hand communicator, and the configuration information can be memorized.


● High precision, low power consumption, wide operating temperature range, stable and reliable operation.


● Wide range of use, can form an integrated field installation structure with thermal resistance.


● Electromagnetic compatibility conforms to EN61326-1:2006; EN61000-3-2:2006 + A1:2009


+ A2:2009;EN61000-3-3:2008 standard.


■Technical parameters


enter


Measuring variable temperature


Measurement accuracy 0.2%


See the list of input signal and measuring range for sensor type and measuring range


output


Output current 4~20mA


Load resistance RL≤ (Ue-7.5)/0.021A


Upper and lower limit overflow alarm output current IH = 20.5mA; IL= 3.8mA


Input disconnection alarm output current 22mA


Input short circuit alarm output current 22mA


Sampling period 0.25S Rated value


protection reverse protection


Basic parameters


Supply voltage 7.5~45V, d.c.


Temperature drift 0.01% F.S./℃


Damping time < 5S


Dielectric strength (between input and output) 1500V, a.c.; 1min


Insulation resistance (between input and output) ≥100MΩ


Electromagnetic Compatibility


EN61326-1:2006


EN61000-3-2:2006 + A1:2009 + A2:2009


EN61000-3-3:2008


Minimum range 50℃


Weight 32g


Rated Operating Conditions - Ambient Temperature


Storage temperature -50℃~+105℃


Working temperature -40℃~+85℃


Relative humidity ≤85%


Calibration ambient temperature 23℃


■Input type and measurement range


*Reference conditions: The calibration ambient temperature is 23°C (73.4°F) ± 5°C.


■Configuration settings


Configuration equipment: TT101R smart temperature transmitter handheld operator TC100.


Configurable parameters: input sensor type, input measurement range.


■Dimensions


Sensor Type Graduation Range Output Accuracy


Thermal Resistance (RT)


Pt100 -200℃~+850℃ 0.4℃/0.2%


Pt1000 -200℃~+300℃ 0.4℃/0.2%


Cu50 -50℃~+150℃ 0.4℃/0.2%


Cu100 -50℃~+150℃ 0.4℃/0.2%


※The output accuracy error is the larger of the two values.


 

 