UZC-A01F High temperature and low pressure magnetic level gauge
- tel:0086 550 7623999、0086 550 7623888
- fax:0550-7623199 ext 0
- email:xinguo@xinguo.net
Description
XG / UZC -A01F high temperature and low pressure magnetic liquid level gauge series products are used for liquid level measurement in high temperature and low pressure occasions, the maximum temperature is 450℃, and the maximum working pressure is 2.5MPa. The high temperature and low pressure type magnetic liquid level meter has no blind area in the whole process of measurement, the display is eye-catching, and the reading is intuitive and the measurement range is large. It can be used with XG/UQZ-08 bundled remote transmitter, output 4-20mA remote signal, can be equipped with upper and lower liquid level alarm switches, can realize upper and lower limit liquid level alarm and control, and realize long-distance detection , indicating and controlling.
●Main technical indicators:
Measuring range: 300-15000mm
Measurement accuracy: ±10mm
Cavity material: 304, 321, 316
Working pressure: 1.6MPa, 2.5MPa
Temperature range: ≤450℃
Specific gravity of medium: ≥0.5g/cm³
Medium density difference: ≥0.15g/cm³
Medium viscosity: ≤0.02Pa. S
Output signal, 4-20mA DC600Ω load
Connection flange: DN20, DN25, etc., flange standard HG /T20592-2009
●Order notice:
If other flange standards are used, please specify when ordering.